If you’ve worked on transmission cable projects before, you’d understand the painful process of finding the perfect electrical configuration that complies to allowable voltage drop limits. Most conventional methods of overcoming voltage drop are highly priced, which puts a dent in your project budgets. In this blog, we reveal proven and cost-effective solutions to overcome voltage drop, enabling you to enjoy big savings on cable costs…

Read More »
4 TYPES OF AC AUTOMATIC VOLTAGE REGULATORS FOR MAXIMUM OPERATIONAL RELIABILITY
Voltage Problems

4 Types of AC Automatic Voltage Regulator For Operational Reliability

It is important to choose an ideal AC Automatic Voltage Regulator (AVR) for your facility in order to achieve optimal performance, minimize unnecessary maintenance costs, and ultimately – protect your precious uptime. In this guide, we’ll explore 4 commonly used Automatic Voltage Regulators to optimize your electrical system.

Read More »
Scroll to Top
Form Sent!
Thank you for getting in touch with us.

We will be in contact shortly.

Three Phase

SESL-H-3P-S Model
Large Capacity Rating
200 to 2,000 KVA

 

Enclosure 335
1000W x 1300H x 580D (mm)
250~300 KVA ± 15%
120~200 KVA ± 20%

 

Enclosure 336
1280W x 1480H x 660D (mm)
400 KVA ± 15%
250 KVA ± 20%

 

Enclosure 337H
1880W x 1950H x 880D (mm)
500 KVA ± 15%
300 KVA ± 20%

 

Enclosure 339
1470W x 1950H x 1340D (mm)
600 ~ 1,500 KVA ± 15%
400 ~ 1,000 KVA ± 20%
300 ~ 750 KVA ± 25%
300 ~ 600 KVA ± 30%

Three Phase

SES-H-3P-S Model
Added I/P Breaker Protection
60 to 1,000 KVA

 

Enclosure 333
490W x 800H x 990D (mm)
≤ 100 KVA ± 15%

 

Enclosure 334
540W x 900H x 1000D (mm)
120 – 150 KVA ± 15%

 

Enclosure 335
1000W x 1300H x 580D (mm)
180 – 300 KVA ± 15%
120 – 200 KVA ± 20%
120 – 150 KVA ± 25%

 

Enclosure 336H
1880W x 1480H x 660D (mm)
400 KVA ± 15%
250 KVA ± 20%
180 ~ 200 KVA ± 25%

 

Enclosure 337H
1880W x 1950H x 880D (mm)
500 KVA ± 15%
300 KVA ± 20%
250 KVA ± 25%

 

Enclosure 339H
2170W x 1950H x 1340D (mm)
600~1,000 KVA ± 15%
400~600 KVA ± 20%
300~400 KVA ± 25%

Single Phase

SES-H-S Model
Added I/P Breaker Protection
1 to 100 KVA

Enclosure 102
270W x 460H x 490D (mm)
≤ 20 KVA ± 30%
≤ 15 KVA ± 20%
≤ 10 KVA ± 25%
≤ 10 KVA ± 15%

Enclosure 103
400W x 580H x 500D (mm)
25 KVA ± 15%
20 KVA ± 20%
15 KVA ± 25%

Enclosure 332
380W x 670H x 780D (mm)
30 KVA ± 15%

Enclosure 333
490W x 800H x 990D (mm)
40 ~ 50 KVA ± 15%
25 ~ 30 KVA ± 20%
20 ~ 25 KVA ± 25%
15 ~ 20 KVA ± 30%

Enclosure 334
540W x 900H x 1000D (mm)
60 ~ 75 KVA ± 15%
40 ~60 KVA ± 20%
30 ~ 50 KVA ± 25%
25 ~ 40 KVA ± 30%