Larger Three Phase Constant Voltage Compensators

Three Phase Constant Voltage CompensatorsThree Phase Volt Drop Compensators / Boosters in ratings from 250 to 1500 kVA

Our Larger Three Phase ranges of Constant Voltage Compensators specifically configured for the needs of larger site applications where the maintenance of a fault tolerant input voltage window for mission critical applications is essential and the general supply infrastructure may already incorporate some of the protection features commonly integrated as standard in our CVC & OCVC-3P-SM or TM ranges.

Available as either Indoor IP20 / NEMA 1 or Outdoor IP54 / NEMA 3 style solutions, the 380 to 415V (H Series) and 200 to 220V (LY Series) Three Phase Volt Drop Compensators ranges are detailed in the TABs below.

 

Volt Drop Compensation

CVCL & OCVCL H-3P-TM Series - 250 to 1500 kVA
380 to 400V Three Phase Indoor (IP20) & Outdoor (IP54) Constant Voltage Compensators with Twin Module Regulation

3P 4W Solution

 CVCL-H-3P-TM Input Voltage Windows

 Also available as 3 Wire (HD) - 3 Wire Without Neutral - Solutions. Please contact us for further details.

 

Downloads

CVCL-H-3P-TM Series Data Sheet: pdf



 

 

Pricing

To obtain a personal price, or to discuss further how we might be able to help your organisation, please feel free

 to either e-mail us
 or call us on +44 (0)870 240 6162
 

Get ADOBE READER  Get Adobe Flash Player

General Technical Specification

  Features   CVC Indoor IP20 / NEMA 1 Models OCVC Outdoor IP54 / NEMA 3 Models
 

  Technology:

 

Servo Electronic - Variable Transformer controlled, series regulation transformer
(buck-boast transformer with secondary wired in series with the load).

  Input Voltage Range:
  (Three Phase, 4 Wire)

 

  S1 - 373V to 430V (L-N: 216 to 253V)
  S2 - 352V to 430V (L-N: 204 to 253V)
  S3 - 332V to 430V (L-N: 192 to 253V)
  S4 - 311V to 430V (L-N: 180 to 253V)
  S5 - 290V to 430V (L-N: 168 to 253V)
  S6 - 270V  to 430V (L-N: 156 to 253V)
  S7 - 249V to 430V (L-N: 144 to 253V)

  Output Voltage:

 

Presettable for any voltage between 380/220V, 400/230V & 415/240V
(Customer to Specify), Three Phase, 4 Wire (3P+N+G/E)

  Output Voltage Accuracy:   ± 1%
  Frequency:   47 - 65Hz
  Response Time:   <1.5ms

  Correction Time:

 

A 10% supply variation will be corrected to within
2.5% in 0.6 seconds

  Efficiency:   98%
  Power Factor:
  Any lagging to 0.95 leading

  Surge Ratings:

  10 x max. current rating for 2 seconds
  3 x max. current rating for 1 minute
  2 x max. current rating for 2 minutes 

  Surge Suppression:

 

TVSS - Protects loads against high-energy Spikes
and Transient Voltages

  Total Harmonic Distortion:    Less than 1% 

  Independent Phase Control:  

 

Maintains each phase voltage stable
irrespective of load unbalance, even up to 100% load unbalance

  Twin Module Regulation:

 

 

Parallel Redundant Voltage Regulation Control Modules (VRCM) on each phase.
Should one Module fail or malfunction the other parallel Module will
operate automatically without causing interruption to the load and 
also without affecting capacity.

  Soft-Switch On: 

 

Ensures the output voltage is set at minimum upon
Switch-On before commencing stabilization

  Environment:

  Temperature range –15 to 45 °C.
  Derate by 2% for each additional °C Up to max 60 °C.
  Suitable for indoor tropical use 95% RH (non-condensing).
  Maximum altitude 1000m.
  Derate by 2.5% for each additional 500m.
  Paint Colour:   RAL 7032 (Grey - Epoxy Powder Coating)

  EMC Conformance: 

 

Complies with BS EN 55022 and the
relevant parts of the BS EN 61000 series of standards 

  CE Conformity:

 

CE Marked - being fully compliant
with European Union Directives 2004/108/EC
(The EMC Directive) and 2006/95/EC (The Low
Voltage Directive)

  Standard Warranty:

 

Three Years / 36 Months
from date of supply

Two Years / 24 Months
from date of supply

  Construction:

 

Enclosures to IP20
(NEMA 1 Style) - BS EN 60529

Enclosures to IP54 
(NEMA 3 Style) - BS EN 60529 

  Features:

 

Over / Low Voltage
Relay (Volt Free Contacts)

Over / Low Voltage
Relay (Volt Free Contacts)

 

Power Module Protection

Power Module Protection

 

Bypass Control Switch

Bypass Control Switch

 

Voltmeter
(Selector Switch)

Voltmeter
(Selector Switch)

 

Ammeter
(Selector Switch)

Ammeter
(Selector Switch)

   

Lightning Surge
Arrestor

  Optional Accessories: 

 

Input Circuit Breaker 

Input Circuit Breaker 

 

Output Circuit Breaker 

Output Circuit Breaker 

 

Frequency Meter

Frequency Meter

 

Over / Low Voltage
Protection

Over / Low Voltage
Protection 

 

Phase Failure
Protection

Phase Failure
Protection 

 

Manual Maintenance
Bypass Switch

Manual Maintenance
Bypass Switch

 

Digital Power Metering

Digital Power Metering

 

AquaStop Protective
Coating

AquaStop Protective
Coating

 

Lightning Surge
Arrestor

 

S1 Models (373 to 430 Volts) - 250 to 1500 kVA

Power
Rating

Max. Amps

 


















IP20 (NEMA 1 Style) Indoor Models   IP54 (NEMA 3 Style) Outdoor Models
@380V @400V @415V AE Model No: 

Dimensions
W x H x D (mm)

Weight
(Kgs)

  AE Model No: 

Dimensions
W x H x D (mm)

Weight
(Kgs)

 
250 kVA 379 360 347 CVCL-250H-3P-S1-TM 1280 x 1480 x 660 576   OCVCL-250H-3P-S1-TM 1280 x 1600 x 920 661
300 kVA 455 432 417 CVCL-300H-3P-S1-TM 1280 x 1480 x 660 601   OCVCL-300H-3P-S1-TM 1280 x 1600 x 920
686
350 kVA 531 505 486 CVCL-350H-3P-S1-TM 1280 x 1480 x 660 651   OCVCL-350H-3P-S1-TM 1280 x 1600 x 920 736
400 kVA 607 577 556 CVCL-400H-3P-S1-TM 1280 x 1480 x 660 661   OCVCL-400H-3P-S1-TM 1280 x 1600 x 920 746
450 kVA 683 649 625 CVCL-450H-3P-S1-TM 1280 x 1950 x 880 951   OCVCL-450H-3P-S1-TM 1280 x 2020 x 1140 1046
500 kVA 759 721 695 CVCL-500H-3P-S1-TM 1280 x 1950 x 880 961   OCVCL-500H-3P-S1-TM 1280 x 2020 x 1140
1056
600 kVA 911 865 834 CVCL-600H-3P-S1-TM 1280 x 1950 x 880 1011   OCVCL-600H-3P-S1-TM 1280 x 2020 x 1140 1106
650 kVA 987 937 904 CVCL-650H-3P-S1-TM 1280 x 1950 x 880 1131   OCVCL-650H-3P-S1-TM 1280 x 2020 x 1140 1226
700 kVA 1063 1010 973 CVCL-700H-3P-S1-TM 1280 x 1950 x 880 1141   OCVCL-700H-3P-S1-TM 1280 x 2020 x 1140 1236
750 kVA 1139 1082 1043 CVCL-750H-3P-S1-TM 1280 x 1950 x 880 1151   OCVCL-750H-3P-S1-TM 1280 x 2020 x 1140 1246
800 kVA 1215 1154 1112 CVCL-800H-3P-S1-TM 1340 x 1950 x 1280 1561   OCVCL-800H-3P-S1-TM 1340 x 2020 x 1540 1666
900 kVA 1367 1298 1251 CVCL-900H-3P-S1-TM 1340 x 1950 x 1280 1571   OCVCL-900H-3P-S1-TM 1340 x 2020 x 1540 1676
1000 kVA 1518 1443 1390 CVCL-1000H-3P-S1-TM 1340 x 1950 x 1280 1581   OCVCL-1000H-3P-S1-TM 1340 x 2020 x 1540 1686
1200 kVA 1822 1731 1669 CVCL-1200H-3P-S1-TM 1340 x 1950 x 1280 1671   OCVCL-1200H-3P-S1-TM 1340 x 2020 x 1540 1776
1250 kVA 1898 1803 1738 CVCL-1250H-3P-S1-TM 1340 x 1950 x 1280
1731   OCVCL-1250H-3P-S1-TM 1340 x 2020 x 1540 1836
1500 kVA 2278 2164 2086 CVCL-1500H-3P-S1-TM 1470 x 1950 x 1340 2001   OCVCL-1500H-3P-S1-TM    
 
   Note:    Other voltage configurations available upon enquiry / order. 
  For smaller rated solutions please refer to our CVC-H-3P-S1-SM range.
  Optional Accessories added may affect dimensions and weights - subject to confirmation.

S2 Models (352 to 430 Volts) - 250 to 1200 kVA

Power
Rating

Max. Amps

 


















IP20 (NEMA 1 Style) Indoor Models   IP54 (NEMA 3 Style) Outdoor Models
@380V @400V @415V AE Model No: 

Dimensions
W x H x D (mm)

Weight
(Kgs)

  AE Model No: 

Dimensions
W x H x D (mm)

Weight
(Kgs)

 
250 kVA 379 360 347 CVCL-250H-3P-S2-TM 1280 x 1480 x 660 701   OCVCL-250H-3P-S2-TM 1280 x 1600 x 920 786
300 kVA 455 432 417 CVCL-300H-3P-S2-TM 1280 x 1480 x 660 601   OCVCL-300H-3P-S2-TM 1280 x 1600 x 920
886
350 kVA 531 505 486 CVCL-350H-3P-S2-TM 1280 x 1950 x 880 956   OCVCL-350H-3P-S2-TM 1280 x 2020 x 1140 1051
400 kVA 607 577 556 CVCL-400H-3P-S2-TM 1280 x 1950 x 880 966   OCVCL-400H-3P-S2-TM 1280 x 2020 x 1140 1061
450 kVA 683 649 625 CVCL-450H-3P-S2-TM 1280 x 1950 x 880 1006   OCVCL-450H-3P-S2-TM 1280 x 2020 x 1140 1101
500 kVA 759 721 695 CVCL-500H-3P-S2-TM 1280 x 1950 x 880 1016   OCVCL-500H-3P-S2-TM 1280 x 2020 x 1140
1111
600 kVA 911 865 834 CVCL-600H-3P-S2-TM 1340 x 1950 x 1280 1401   OCVCL-600H-3P-S2-TM 1340 x 2020 x 1540 1506
650 kVA 987 937 904 CVCL-650H-3P-S2-TM 1340 x 1950 x 1280 1461   OCVCL-650H-3P-S2-TM 1340 x 2020 x 1540 1566
700 kVA 1063 1010 973 CVCL-700H-3P-S2-TM 1340 x 1950 x 1280 1471   OCVCL-700H-3P-S2-TM 1340 x 2020 x 1540 1576
750 kVA 1139 1082 1043 CVCL-750H-3P-S2-TM 1340 x 1950 x 1280 1481   OCVCL-750H-3P-S2-TM 1340 x 2020 x 1540 1586
800 kVA 1215 1154 1112 CVCL-800H-3P-S2-TM 1340 x 1950 x 1280 1761   OCVCL-800H-3P-S2-TM 1340 x 2020 x 1540 1866
900 kVA 1367 1298 1251 CVCL-900H-3P-S2-TM 1340 x 1950 x 1280 1781   OCVCL-900H-3P-S2-TM 1340 x 2020 x 1540 1886
1000 kVA 1518 1443 1390 CVCL-1000H-3P-S2-TM 1340 x 1950 x 1280 1801   OCVCL-1000H-3P-S2-TM 1340 x 2020 x 1540 1906
1200 kVA 1822 1731 1669 CVCL-1200H-3P-S2-TM 1340 x 1950 x 1280 2181   OCVCL-1200H-3P-S2-TM 1340 x 2020 x 1540 2286
 
   Note:    Other voltage configurations available upon enquiry / order. 
  For smaller rated solutions please refer to our CVC-H-3P-S2-SM range.
  Optional Accessories added may affect dimensions and weights - subject to confirmation.

S3 Models (332 to 430 Volts) - 250 to 1000 kVA

Power
Rating

Max. Amps

 


















IP20 (NEMA 1 Style) Indoor Models   IP54 (NEMA 3 Style) Outdoor Models
@380V @400V @415V AE Model No: 

Dimensions
W x H x D (mm)

Weight
(Kgs)

  AE Model No: 

Dimensions
W x H x D (mm)

Weight
(Kgs)

 
250 kVA 379 360 347 CVCL-250H-3P-S3-TM 1280 x 1950 x 880 901   OCVCL-250H-3P-S3-TM 1280 x 2020 x 1140 996
300 kVA 455 432 417 CVCL-300H-3P-S3-TM 1280 x 1950 x 880 971   OCVCL-300H-3P-S3-TM 1280 x 2020 x 1140 1066
350 kVA 531 505 486 CVCL-350H-3P-S3-TM 1280 x 1950 x 880 1281   OCVCL-350H-3P-S3-TM 1280 x 2020 x 1140 1376
400 kVA 607 577 556 CVCL-400H-3P-S3-TM 1340 x 1950 x 1280 1301   OCVCL-400H-3P-S3-TM 1340 x 2020 x 1540 1406
450 kVA 683 649 625 CVCL-450H-3P-S3-TM 1340 x 1950 x 1280 1411   OCVCL-450H-3P-S3-TM 1340 x 2020 x 1540 1516
500 kVA 759 721 695 CVCL-500H-3P-S3-TM 1340 x 1950 x 1280 1431   OCVCL-500H-3P-S3-TM 1340 x 2020 x 1540 1536
600 kVA 911 865 834 CVCL-600H-3P-S3-TM 1340 x 1950 x 1280 1481   OCVCL-600H-3P-S3-TM 1340 x 2020 x 1540 1586
650 kVA 987 937 904 CVCL-650H-3P-S3-TM 1340 x 1950 x 1280 1821   OCVCL-650H-3P-S3-TM 1340 x 2020 x 1540 1926
700 kVA 1063 1010 973 CVCL-700H-3P-S3-TM 1340 x 1950 x 1280 1841   OCVCL-700H-3P-S3-TM 1340 x 2020 x 1540 1946
750 kVA 1139 1082 1043 CVCL-750H-3P-S3-TM 1340 x 1950 x 1280 1861   OCVCL-750H-3P-S3-TM 1340 x 2020 x 1540 1966
800 kVA 1215 1154 1112 CVCL-800H-3P-S3-TM 1470 x 1950 x 1340 2181   OCVCL-800H-3P-S3-TM    
900 kVA 1367 1298 1251 CVCL-900H-3P-S3-TM 1470 x 1950 x 1340 2201   OCVCL-900H-3P-S3-TM    
1000 kVA 1518 1443 1390 CVCL-1000H-3P-S3-TM 1470 x 1950 x 1340 2221   OCVCL-1000H-3P-S3-TM    
 
   Note:    Other voltage configurations available upon enquiry / order. 
  For smaller rated solutions please refer to our CVC-H-3P-S3-SM range.
  Optional Accessories added may affect dimensions and weights - subject to confirmation.

S4 Models (311 to 430 Volts) - 250 to 750 kVA

Power
Rating

Max. Amps

 


















IP20 (NEMA 1 Style) Indoor Models   IP54 (NEMA 3 Style) Outdoor Models
@380V @400V @415V AE Model No: 

Dimensions
W x H x D (mm)

Weight
(Kgs)

  AE Model No: 

Dimensions
W x H x D (mm)

Weight
(Kgs)

 
250 kVA 379 360 347 CVCL-250H-3P-S4-TM 1280 x 1950 x 880 1001   OCVCL-250H-3P-S4-TM 1280 x 2020 x 1140 1096
300 kVA 455 432 417 CVCL-300H-3P-S4-TM 1340 x 1950 x 1280 1301   OCVCL-300H-3P-S4-TM 1340 x 2020 x 1540 1406
350 kVA 531 505 486 CVCL-350H-3P-S4-TM 1340 x 1950 x 1280 1411   OCVCL-350H-3P-S4-TM 1340 x 2020 x 1540 1516
400 kVA 607 577 556 CVCL-400H-3P-S4-TM 1340 x 1950 x 1280 1431   OCVCL-400H-3P-S4-TM 1340 x 2020 x 1540 1536
450 kVA 683 649 625 CVCL-450H-3P-S4-TM 1340 x 1950 x 1280 1681   OCVCL-450H-3P-S4-TM 1340 x 2020 x 1540 1786
500 kVA 759 721 695 CVCL-500H-3P-S4-TM 1340 x 1950 x 1280 1701   OCVCL-500H-3P-S4-TM 1340 x 2020 x 1540 1806
600 kVA 911 865 834 CVCL-600H-3P-S4-TM 1340 x 1950 x 1280 1881   OCVCL-600H-3P-S4-TM 1340 x 2020 x 1540 1986
650 kVA 987 937 904 CVCL-650H-3P-S4-TM 1470 x 1950 x 1340 2141   OCVCL-650H-3P-S4-TM    
700 kVA 1063 1010 973 CVCL-700H-3P-S4-TM 1470 x 1950 x 1340 2171   OCVCL-700H-3P-S4-TM    
750 kVA 1139 1082 1043 CVCL-750H-3P-S4-TM 1470 x 1950 x 1340 2201   OCVCL-750H-3P-S4-TM    
 
   Note:    Other voltage configurations available upon enquiry / order. 
  For smaller rated solutions please refer to our CVC-H-3P-S4-SM range.
  Optional Accessories added may affect dimensions and weights - subject to confirmation.

S5 Models (290 to 430 Volts) - 250 to 600 kVA

Power
Rating

Max. Amps

 


















IP20 (NEMA 1 Style) Indoor Models   IP54 (NEMA 3 Style) Outdoor Models
@380V @400V @415V AE Model No: 

Dimensions
W x H x D (mm)

Weight
(Kgs)

  AE Model No: 

Dimensions
W x H x D (mm)

Weight
(Kgs)

 
250 kVA 379 360 347 CVCL-250H-3P-S5-TM 1340 x 1950 x 1280 1601   OCVCL-250H-3P-S5-TM 1340 x 2020 x 1540 1706
300 kVA 455 432 417 CVCL-300H-3P-S5-TM 1340 x 1950 x 1280 1781   OCVCL-300H-3P-S5-TM 1340 x 2020 x 1540 1886
350 kVA 531 505 486 CVCL-350H-3P-S5-TM 1340 x 1950 x 1280 1831   OCVCL-350H-3P-S5-TM 1340 x 2020 x 1540 1936
400 kVA 607 577 556 CVCL-400H-3P-S5-TM 1340 x 1950 x 1280 1861   OCVCL-400H-3P-S5-TM 1340 x 2020 x 1540 1966
450 kVA 683 649 625 CVCL-450H-3P-S5-TM 1340 x 1950 x 1280 1921   OCVCL-450H-3P-S5-TM 1340 x 2020 x 1540 2026
500 kVA 759 721 695 CVCL-500H-3P-S5-TM 1340 x 1950 x 1280 2001   OCVCL-500H-3P-S5-TM 1340 x 2020 x 1540 2106
600 kVA 911 865 834 CVCL-600H-3P-S5-TM 1470 x 1950 x 1340 2201   OCVCL-600H-3P-S5-TM    
 
   Note:    Other voltage configurations available upon enquiry / order. 
  For smaller rated solutions please refer to our CVC-H-3P-S5-SM range.
  Optional Accessories added may affect dimensions and weights - subject to confirmation.

S6 Models (270 to 430 Volts) - 250 to 500 kVA

Power
Rating

Max. Amps

 


















IP20 (NEMA 1 Style) Indoor Models   IP54 (NEMA 3 Style) Outdoor Models
@380V @400V @415V AE Model No: 

Dimensions
W x H x D (mm)

Weight
(Kgs)

  AE Model No: 

Dimensions
W x H x D (mm)

Weight
(Kgs)

 
250 kVA 379 360 347 CVCL-250H-3P-S6-TM 1340 x 1950 x 1280 1681   OCVCL-250H-3P-S6-TM 1340 x 2020 x 1540 1786
300 kVA 455 432 417 CVCL-300H-3P-S6-TM 1340 x 1950 x 1280 1851   OCVCL-300H-3P-S6-TM 1340 x 2020 x 1540 1956
350 kVA 531 505 486 CVCL-350H-3P-S6-TM 1340 x 1950 x 1280 1951   OCVCL-350H-3P-S6-TM 1340 x 2020 x 1540 2052
400 kVA 607 577 556 CVCL-400H-3P-S6-TM 1340 x 1950 x 1280 1981   OCVCL-400H-3P-S6-TM 1340 x 2020 x 1540 2086
450 kVA 683 649 625 CVCL-450H-3P-S6-TM 1470 x 1950 x 1340 2231   OCVCL-450H-3P-S6-TM    
500 kVA 759 721 695 CVCL-500H-3P-S6-TM 1470 x 1950 x 1340 2261   OCVCL-500H-3P-S6-TM    
 
   Note:    Other voltage configurations available upon enquiry / order. 
  For smaller rated solutions please refer to our CVC-H-3P-S6-SM range.
  Optional Accessories added may affect dimensions and weights - subject to confirmation.

S7 Models (249 to 430 Volts) - 250 to 400 kVA

Power
Rating

Max. Amps

 


















IP20 (NEMA 1 Style) Indoor Models   IP54 (NEMA 3 Style) Outdoor Models
@380V @400V @415V AE Model No: 

Dimensions
W x H x D (mm)

Weight
(Kgs)

  AE Model No: 

Dimensions
W x H x D (mm)

Weight
(Kgs)

 
250 kVA 379 360 347 CVCL-250H-3P-S7-TM 1340 x 1950 x 1280 1851   OCVCL-250H-3P-S7-TM 1340 x 2020 x 1540 1956
300 kVA 455 432 417 CVCL-300H-3P-S7-TM 1340 x 1950 x 1280
1981   OCVCL-300H-3P-S7-TM 1340 x 2020 x 1540 2086
350 kVA 531 505 486 CVCL-350H-3P-S7-TM 1340 x 1950 x 1280 2231   OCVCL-350H-3P-S7-TM 1340 x 2020 x 1540 2336
400 kVA 607 577 556 CVCL-400H-3P-S7-TM 1340 x 1950 x 1280 2261   OCVCL-400H-3P-S7-TM 1340 x 2020 x 1540 2366
 
   Note:    Other voltage configurations available upon enquiry / order. 
  For smaller rated solutions please refer to our CVC-H-3P-S7-SM range.
  Optional Accessories added may affect dimensions and weights - subject to confirmation.

     Copyright © Ashley-Edison (UK) reserves the right to change any or all of the specifications indicated or implied without prior notice. E&OE

Volt Drop Compensation

CVCL & OCVCL LY-3P-TM Series - 250 to 500 kVA
200 to 220V Three Phase Indoor (IP20) & Outdoor (IP54) Constant Voltage Compensators with Twin Module Regulation

3P 4W Solution

 CVCL-LY-3P-TM Input Voltage Windows

 Also available as 3 Wire (LD) - 3 Wire Without Neutral - Solutions. Please contact us for further details.

 

Downloads

CVCL-LY-3P-TM Series Data Sheet: pdf



 

 

Pricing

To obtain a personal price, or to discuss further how we might be able to help your organisation, please feel free

 to either e-mail us
 or call us on +44 (0)870 240 6162
 

Get ADOBE READER  Get Adobe Flash Player

General Technical Specification

  Features   CVC Indoor IP20 / NEMA 1 Models OCVC Outdoor IP54 / NEMA 3 Models
 

  Technology:

 

Servo Electronic - Variable Transformer controlled, series regulation transformer
(buck-boast transformer with secondary wired in series with the load).

  Input Voltage Range:
  (Three Phase, 4 Wire)

 

  S1 - 198V to 230V (L-N: 114 to 132V)
  S2 - 187V to 230V (L-N: 108 to 132V)
  S3 - 176V to 230V (L-N: 102 to 132V)
  S4 - 165V to 230V (L-N: 96 to 132V)

  Output Voltage:

 

Presettable for any voltage between 200/115V, 208/120V & 220/127V
(Customer to Specify), Three Phase, 4 Wire (3P+N+G/E)

  Output Voltage Accuracy:   ± 1%
  Frequency:   47 - 65Hz
  Response Time:   <1.5ms

  Correction Time:

 

A 10% supply variation will be corrected to within
2.5% in 0.6 seconds

  Efficiency:   98%
  Power Factor:
  Any lagging to 0.95 leading

  Surge Ratings:

  10 x max. current rating for 2 seconds
  3 x max. current rating for 1 minute
  2 x max. current rating for 2 minutes 

  Surge Suppression:

 

TVSS - Protects loads against high-energy Spikes
and Transient Voltages

  Total Harmonic Distortion:    Less than 1% 

  Independent Phase Control:  

 

Maintains each phase voltage stable
irrespective of load unbalance, even up to 100% load unbalance

  Twin Module Regulation:

 

 

Parallel Redundant Voltage Regulation Control Modules (VRCM) on each phase.
Should one Module fail or malfunction the other parallel Module will
operate automatically without causing interruption to the load and 
also without affecting capacity.

  Soft-Switch On: 

 

Ensures the output voltage is set at minimum upon
Switch-On before commencing stabilization

  Environment:

  Temperature range –15 to 45 °C.
  Derate by 2% for each additional °C Up to max 60 °C.
  Suitable for indoor tropical use 95% RH (non-condensing).
  Maximum altitude 1000m.
  Derate by 2.5% for each additional 500m.
  Paint Colour:   RAL 7032 (Grey - Epoxy Powder Coating)

  EMC Conformance: 

 

Complies with BS EN 55022 and the
relevant parts of the BS EN 61000 series of standards 

  CE Conformity:

 

CE Marked - being fully compliant
with European Union Directives 2004/108/EC
(The EMC Directive) and 2006/95/EC (The Low
Voltage Directive)

  Standard Warranty:

 

Three Years / 36 Months
from date of supply

Two Years / 24 Months
from date of supply

  Construction:

 

Enclosures to IP20
(NEMA 1 Style) - BS EN 60529

Enclosures to IP54 
(NEMA 3 Style) - BS EN 60529 

  Features:

 

Over / Low Voltage
Relay (Volt Free Contacts)

Over / Low Voltage
Relay (Volt Free Contacts)

 

Power Module Protection

Power Module Protection

 

Bypass Control Switch

Bypass Control Switch

 

Voltmeter
(Selector Switch)

Voltmeter
(Selector Switch)

 

Ammeter
(Selector Switch)

Ammeter
(Selector Switch)

   

Lightning Surge
Arrestor

  Optional Accessories: 

 

Input Circuit Breaker 

Input Circuit Breaker 

 

Output Circuit Breaker 

Output Circuit Breaker 

 

Frequency Meter

Frequency Meter

 

Over / Low Voltage
Protection

Over / Low Voltage
Protection 

 

Phase Failure
Protection

Phase Failure
Protection 

 

Manual Maintenance
Bypass Switch

Manual Maintenance
Bypass Switch

 

Digital Power Metering

Digital Power Metering

 

AquaStop Protective
Coating

AquaStop Protective
Coating

 

Lightning Surge
Arrestor

 

S1 Models (198 to 230 Volts) - 250 to 500 kVA

Power
Rating

Max. Amps

 


















IP20 (NEMA 1 Style) Indoor Models   IP54 (NEMA 3 Style) Outdoor Models
@200V @208V @220V AE Model No: 

Dimensions
W x H x D (mm)

Weight
(Kgs)

  AE Model No: 

Dimensions
W x H x D (mm)

Weight
(Kgs)

 
250 kVA 721 693 655 CVCL-250LY-3P-S1-TM

Dimensions and Weights
available on Request

  OCVCL-250LY-3P-S1-TM

Dimensions and Weights
available on Request

300 kVA 865 832 787 CVCL-300LY-3P-S1-TM   OCVCL-300LY-3P-S1-TM
350 kVA 1010 971 918 CVCL-350LY-3P-S1-TM   OCVCL-350LY-3P-S1-TM
400 kVA 1154 1110 1049 CVCL-400LY-3P-S1-TM   OCVCL-400LY-3P-S1-TM
450 kVA 1298 1248 1180 CVCL-450LY-3P-S1-TM   OCVCL-450LY-3P-S1-TM
500 kVA 1443 1387 1311 CVCL-500LY-3P-S1-TM   OCVCL-500LY-3P-S1-TM
 
   Note:    Other voltage configurations available upon enquiry / order. 
  For smaller rated solutions please refer to our CVC-LY-3P-S1-SM range.
  Optional Accessories added may affect dimensions and weights - subject to confirmation.

S2 Models (187 to 230 Volts) - 250 to 500 kVA

Power
Rating

Max. Amps

 


















IP20 (NEMA 1 Style) Indoor Models   IP54 (NEMA 3 Style) Outdoor Models
@200V @208V @220V AE Model No: 

Dimensions
W x H x D (mm)

Weight
(Kgs)

  AE Model No: 

Dimensions
W x H x D (mm)

Weight
(Kgs)

 
250 kVA 721 693 655 CVCL-250LY-3P-S2-TM

Dimensions and Weights
available on Request

  OCVCL-250LY-3P-S2-TM

Dimensions and Weights
available on Request

300 kVA 865 832 787 CVCL-300LY-3P-S2-TM   OCVCL-300LY-3P-S2-TM
350 kVA 1010 971 918 CVCL-350LY-3P-S2-TM   OCVCL-350LY-3P-S2-TM
400 kVA 1154 1110 1049 CVCL-400LY-3P-S2-TM   OCVCL-400LY-3P-S2-TM
450 kVA 1298 1248 1180 CVCL-450LY-3P-S2-TM   OCVCL-450LY-3P-S2-TM
500 kVA 1443 1387 1311 CVCL-500LY-3P-S2-TM   OCVCL-500LY-3P-S2-TM
 
   Note:    Other voltage configurations available upon enquiry / order. 
  For smaller rated solutions please refer to our CVC-LY-3P-S2-SM range.
  Optional Accessories added may affect dimensions and weights - subject to confirmation.

S3 Models (176 to 230 Volts) - 250 to 400 kVA

Power
Rating

Max. Amps

 


















IP20 (NEMA 1 Style) Indoor Models   IP54 (NEMA 3 Style) Outdoor Models
@200V @208V @220V AE Model No: 

Dimensions
W x H x D (mm)

Weight
(Kgs)

  AE Model No: 

Dimensions
W x H x D (mm)

Weight
(Kgs)

 
250 kVA 721 693 655 CVCL-250LY-3P-S3-TM

Dimensions and Weights
available on Request

  OCVCL-250LY-3P-S3-TM

Dimensions and Weights
available on Request

300 kVA 865 832 787 CVCL-300LY-3P-S3-TM   OCVCL-300LY-3P-S3-TM
350 kVA 1010 971 918 CVCL-350LY-3P-S3-TM   OCVCL-350LY-3P-S3-TM
400 kVA 1154 1110 1049 CVCL-400LY-3P-S3-TM   OCVCL-400LY-3P-S3-TM
 
   Note:    Other voltage configurations available upon enquiry / order. 
  For smaller rated solutions please refer to our CVC-LY-3P-S3-SM range.
  Optional Accessories added may affect dimensions and weights - subject to confirmation.

S4 Models (165 to 230 Volts) - 250 to 300 kVA

Power
Rating

Max. Amps

 


















IP20 (NEMA 1 Style) Indoor Models   IP54 (NEMA 3 Style) Outdoor Models
@200V @208V @220V AE Model No: 

Dimensions
W x H x D (mm)

Weight
(Kgs)

  AE Model No: 

Dimensions
W x H x D (mm)

Weight
(Kgs)

 
250 kVA 721 693 655 CVCL-250LY-3P-S4-TM

Dimensions and Weights
available on Request

  OCVCL-250LY-3P-S4-TM

Dimensions and Weights
available on Request

300 kVA 865 832 787 CVCL-300LY-3P-S4-TM   OCVCL-300LY-3P-S4-TM
 
   Note:    Other voltage configurations available upon enquiry / order. 
  For smaller rated solutions please refer to our CVC-LY-3P-S4-SM range.
  Optional Accessories added may affect dimensions and weights - subject to confirmation.

     Copyright © Ashley-Edison (UK) reserves the right to change any or all of the specifications indicated or implied without prior notice. E&OE




This website uses 'cookies' to give you the best, most relevant experience. Using this website means you’re OK with this. You can change which cookies are set at any time - and find out more about them - by following this link, or by clicking the cookie link at the bottom of any page.
This message will close within 20 seconds.

Accept all cookies